Diodes Characteristics & Boltzman Constant, DCBC-01 Diodes Characteristics & Boltzman Constant, DCBC-01
Diodes Characteristics & Boltzman Constant, DCBC-01
Diodes Characteristics & Boltzman Constant, DCBC-01

Diodes Characteristics & Boltzman Constant, DCBC-01

Product Details:

  • Color Grey
  • Weight 10 Kg Kilograms (kg)
  • Application Laboratory Experiment
  • Usage Laboratory Experiment
  • Material Electronics
  • Display Type Digital
  • Click to View more
X

Diodes Characteristics & Boltzman Constant, DCBC-01 Price And Quantity

  • 1 Piece

Diodes Characteristics & Boltzman Constant, DCBC-01 Product Specifications

  • Electronics
  • 10 Kg Kilograms (kg)
  • Grey
  • Laboratory Experiment
  • Digital
  • Laboratory Experiment

Diodes Characteristics & Boltzman Constant, DCBC-01 Trade Information

  • Cash Against Delivery (CAD), Cash on Delivery (COD), Delivery Point (DP), Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • 100 Piece Per Month
  • 1 Week
  • Contact us for information regarding our sample policy
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
  • All India
  • ISO 9001: 2015 CE

Product Description

Diodes Characteristics & Boltzman Constant, Dcbc-01

The set-up is provided with a booklet which contains its theory of operation, description, suggestions and discussion of the experiments that may be performed with it.

The experimental set-up consists of the following:

  • Diodes: Rectifier-4007 (Si), Signal diode-1N34 (Ge), Zener 4.7V, LED and transistor BC-109
  • 3 digit DPM which can measure diode voltage and current through op-amp circuit. This provides near ideal measurements.
  • Circuit to display forward/reverse characteristics of the diodes on a double trace CRO.
  • IC regulated internal power supplies

The experimental set-up is complete in all respect, except a measuring CRO.



Comprehensive Laboratory Instrument for Diode and Boltzmann Studies

The DCBC-01 brings together advanced digital display technology and robust materials to create a dependable instrument for analyzing diodes and investigating the Boltzmann constant. Its substantial build ensures stability during experimental procedures, while the user-friendly interface supports seamless operation. The device is crafted to enhance laboratory workflows and foster deeper scientific insights.


Engineered for Accuracy and Educational Value

Designed specifically for laboratory experiments, the DCBC-01 emphasizes accuracy and repeatability. Its digital interface ensures precise measurement readings, which is essential for experiments involving diode characteristics and fundamental constants. This equipment serves both teaching and research purposes, making complex concepts accessible through hands-on experimentation.

FAQ's of Diodes Characteristics & Boltzman Constant, DCBC-01:


Q: How is the Diodes Characteristics & Boltzman Constant, DCBC-01 utilized in laboratory experiments?

A: The DCBC-01 is used to measure and study the properties of diodes and to experimentally determine the Boltzmann constant. Students and researchers connect diodes to the device and utilize its digital display to record and analyze voltage, current, and temperature responses under controlled conditions.

Q: What is the main benefit of using this instrument in laboratory settings?

A: The device offers precise digital measurements and durable construction, making it highly accurate and reliable for repeated laboratory experimentation. It aids in the clear understanding of semiconductor physics and the evaluation of fundamental physical constants.

Q: When should a laboratory opt to use the DCBC-01 for experiments?

A: Laboratories should use the DCBC-01 when conducting experiments related to diode characteristics, temperature dependence, or when an accurate determination of the Boltzmann constant is required as part of educational curricula or research projects.

Q: Where is the Diodes Characteristics & Boltzman Constant, DCBC-01 manufactured and supplied from?

A: The DCBC-01 is manufactured, exported, and supplied from India, ensuring adherence to stringent quality standards for scientific equipment.

Q: What is the process for measuring diode characteristics with this device?

A: To measure diode characteristics, connect the diode sample to the DCBC-01, follow the device instructions to vary voltage and temperature, and use the digital display to observe the corresponding current changes. This data allows plotting of I-V and temperature-dependent curves.

Q: How does the digital display enhance the experimental process?

A: The digital display provides immediate and accurate readings, reducing human error and allowing for more precise data gathering. This streamlines the experiment, enabling students and researchers to focus on analysis rather than manual measurement or calculation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Physics & Material Sc. Lab Experiments' category



Back to top